Saybolt universal viscosity (SUV), and the related Saybolt FUROL viscosity (SFV), are specific standardised tests producing measures of kinematic viscosity.
FUROL is an acronym for fuel and road oil. Saybolt universal viscosity is specified by the ASTM D2161. Both tests are considered obsolete to other measures of kinematic viscosity, but their results are quoted widely in technical literature.
In both tests, the time taken for 60 ml of the liquid, held at a specific temperature, to flow through a calibrated tube, is measured, using a Saybolt viscometer. The Saybolt universal viscosity test occurs at 100 °F (38 °C), or more recently, 40 °C (104 °F). The Saybolt FUROL viscosity test occurs at 120 °F (49 °C), or more recently, 50 °C (122 °F), and uses a larger calibrated tube. This provides for the testing of more viscous fluids, with the result being approximately 1⁄10 of the universal viscosity.
The test results are specified in seconds (s), more often than not referencing the test: Saybolt universal seconds (SUS); seconds, Saybolt universal (SSU); seconds, Saybolt universal viscosity (SSUV); and Saybolt FUROL seconds (SFS); seconds, Saybolt FUROL (SSF). The precise temperature at which the test is performed is often specified as well.
This article uses material from the Wikipedia English article Saybolt universal viscosity, which is released under the Creative Commons Attribution-ShareAlike 3.0 license ("CC BY-SA 3.0"); additional terms may apply (view authors). Content is available under CC BY-SA 4.0 unless otherwise noted. Images, videos and audio are available under their respective licenses.
®Wikipedia is a registered trademark of the Wiki Foundation, Inc. Wiki English (DUHOCTRUNGQUOC.VN) is an independent company and has no affiliation with Wiki Foundation.