Poweredge

The PowerEdge (PE) line is Dell's server computer product line.

PowerEdge machines come configured as tower, rack-mounted, or blade servers. Dell uses a consistent chip-set across servers in the same generation regardless of packaging, allowing for a common set of drivers and system-images.

Dell PowerEdge
Poweredge
Poweredge
Dell PowerEdge rackmount servers
DeveloperDell
TypeServer
Release date1994; 30 years ago (1994)
Operating systemWindows Server
Linux
CPUx86 (1994–current);
Itanium (circa 2005)
PredecessorPowerLine SE
Poweredge
Rack-mounted 11th generation PowerEdge servers
Poweredge
Rack-mountable 11th generation (11G) PowerEdge R610 server with the case opened and the front bezel removed

Original equipment manufacturers (OEMs) and value-added resellers also offer solutions based on PowerEdge servers. Loaded with custom software and with minor cosmetic changes, Dell's servers form the underlying hardware in certain appliances from IronPort, Google,Exinda Networks, and Enterasys.

History

The first PowerEdge systems were released in February 1994. The initial PowerEdge line comprised a range of 15 models, with the lowest-end entries powered by Intel's i486 processor and the highest-end entries powered by the newest Pentium processors. The PowerEdge replaced Dell's earlier PowerLine SE server range.

Most PowerEdge servers use the x86 architecture. The early exceptions to this, the PowerEdge 3250, PowerEdge 7150, and PowerEdge 7250, used Intel's Itanium processor, but Dell abandoned Itanium in 2005 after failing to find adoption in the marketplace. The partnership between Intel and Dell remained close, with Intel remaining the exclusive source of processors in Dell's servers until 2006. In May 2006 Dell announced that it also intended to develop servers using AMD Opteron processors. The first Opteron-based PowerEdge systems, the PowerEdge 6950 and the PowerEdge SC1435, appeared in October 2006.

In 2007 the PowerEdge line accounted for approximately 15% of Dell's overall revenue from computer-hardware sales. In subsequent years Dell made the transition from a pure hardware vendor to a solutions-provider and services company, as evidenced, for example, by the acquisition of Perot Systems and KACE Networks and the setup of a special global services department within Dell.

PowerEdge RAID Controller

Dell uses the name PowerEdge RAID Controller (PERC) for proprietary versions of its RAID computer storage controllers. The related software in the PERC Fault Management Suite offered facilities such as the Background Patrol read, which aims to fix bad sectors on online RAID disks running under some of the PERC controllers around 2006. These cards were equipped with hardware from LSI Corporation or Intel, 256 MBytes of memory (upgradeable on the 5/i to 512 MB), support up to 8x SATA 3.0 Gbit/s drives without the use of expanders. They had an optional Battery Backup Unit (BBU) to allow more flexible use of the memory during writes, enhancing performance in RAID5 and 6, and operate over the PCI Express interface.

Chassis systems

Although PowerEdge is mainly used to refer to servers there are a few systems where the term PowerEdge refers to systems of which servers are (just) a part. Examples of these usages are:

    PowerEdge M1000e - the Dell blade-server system where the complete system uses the term PowerEdge, and M1000e refers to the chassis and the complete combination of components in them. The individual non-server components have also their own name in their 'own' family such as PowerConnect M-switches or EqualLogic blade-SAN.
    PowerEdge VRTX - the converged system consisting of (up to) 4 PowerEdge M-blade servers, the built-in storage solution and the I/O networking module.

Model naming convention

Since the introduction of the generation 10 servers in 2007 Dell adopted a standardized method for naming their servers; the name of each server is represented by a letter followed by 3 digits. The letter indicates the type of server: R (for Rack-mountable) indicates a 19" rack-mountable server, M (for Modular) indicates a blade server, while T (for Tower) indicates a stand-alone server.

This letter is then followed by 3 digits:

  • The first digit refers to the number of CPU sockets in the system: 1 to 3 for one socket, 4 to 7 for two sockets, and 9 for four sockets. 8 can be either two or four sockets depending on generation and CPU maker
  • The second digit refers to the generation: 0 for Generation 10, 1 for Generation 11, and so on.
  • The third digit indicates the maker of the CPU: 0 for Intel or 5 for Advanced Micro Devices (AMD).

For example: The Dell PowerEdge M610 was a modular two-socket server of the 11th generation using an Intel CPU while the R605 was a rack-mountable two-socket AMD-based rack-server of the 10th generation.

Prior to the Generation 10 servers, the naming convention was as follows:

  • First digit – Height of the server in rack units
  • Second digit – Generation of server (up to 9th generation)
  • Third digit – Server type (5 for rack server, 0 for tower server, although tower servers could be outfitted with a rack chassis)
  • Fourth digit – Indicated whether blade or independent box (5 for blade, 0 for normal independent box)

Example 1: PowerEdge 2650 ( 2 = 2U server, 6 = 6th generation, 5 = rack server, 0 = normal )

Example 2: PowerEdge 6950 ( 6 = 4U server, 9 = 9th generation, 5 = rack server, 0 = normal )

Example 3: PowerEdge 2800 ( 2 = [based on] 2U server 2850, 8 = 8th generation, 0 = tower server, 0 = normal )

Example 4: PowerEdge 1855 ( 1 = 1U server, 8 = 8th generation, 5 = rack server, 5 = blade )

Most servers had a tower equivalent. For example, the PowerEdge 2800 was the tower equivalent of the 2850. The naming applies to the tower version too, but the tower version will usually be between 5U and 6U.

See also

References

Listen to this article (7 minutes)
Poweredge 
This audio file was created from a revision of this article dated 9 February 2020 (2020-02-09), and does not reflect subsequent edits.


Tags:

Poweredge HistoryPoweredge PowerEdge RAID ControllerPoweredge Chassis systemsPoweredge Model naming conventionPoweredgeBlade serverComputer towerDellDevice driverRack-mountedServer (computing)System image

🔥 Trending searches on Wiki English:

Barbara WaltersDominic Calvert-LewinNicole Mitchell (meteorologist)Mike Johnson (Louisiana politician)Roman ReignsHamasDrop bearCoral CastleUkraineFIFA World CupJennifer PanVarshangalkku SheshamJohn Quincy AdamsMartin Luther King Jr.Charles IIIEliot SumnerI, Robot (film)Orlando BloomSaudi ArabiaNelson MandelaTom CruiseMichael DouglasAaron Taylor-JohnsonJoe ManganielloList of states and territories of the United StatesKim Soo-hyun2023–24 Premier LeagueJennifer LopezRishi SunakAmber HeardBBC World ServiceList of Young Sheldon episodesMagnus CarlsenMoisés AriasNarendra ModiTamim bin Hamad Al ThaniX-Men '97Stephen HawkingJapanGitHubBrad PittKobe Bryant2024 World Snooker ChampionshipChennai Super KingsPornhubDiana, Princess of WalesDwight D. EisenhowerU.S. stateStephen CurryTheodore RooseveltJoseph Stalin2024 Andhra Pradesh Legislative Assembly electionVirat KohliJoe LigonCristiano RonaldoMinnie RipertonThe Jinx (miniseries)New ZealandNew York CityVoice of VietnamAFC Champions LeagueRobloxYellowstone (American TV series)XHamsterTokugawa shogunateFallout (series)James VI and IJessica GunningFallout (video game)Jake GyllenhaalXVideosJodie ComerKylie JennerZack SnyderPakistanTesla, Inc.List of American films of 2024Alex Garland🡆 More